Surge Suppressors

CITEL Surge Suppressors offer shielded construction and are available in DIN-rail or panel-mount mounting styles. The DLAx suppressors feature hybrid SAD-GDT technology and are UL 497B listed and UL 121201 listed for hazardous locations. The DD9 suppressor is designed for RS networks and supports data rates up to 40Mbps, while the DD15 has low-frequency coaxial surge protection with bidirectional protection and a waterproof design. B180 and B480 suppressors offer 20kA Imax, 5kA Imp, and 5kA specification ratings, and <1dB insertion loss and thermoplastic construction. MJ8-POE suppressors are POE++ compatible and feature a 16kA maximum surge discharge capability, maximum transmission of 10Gbps, and a bandwidth of up to 500MHz. CITEL MSP-VMx protectors are combined POE mid-span injector or splitter and SPD and have an integrated power supply injector connector.

Risultati: 10
Seleziona Immagine Codice Produttore Descrizione Scheda dati Disponibilità Prezzi (EUR) Filtra i risultati nella tabella per prezzo unitario in base alla quantità. Qtà RoHS Modello ECAD Tipo Stile di montaggio Stile di terminazione Tensione nominale Corrente nominale Temperatura di lavoro minima Temperatura di lavoro massima Lunghezza Larghezza Altezza
Citel Protezioni da sovratensione industriali DD15-24V D-sub Data Line Surge Protectice Device (SPD) , 24V, 9 wire+G 22A magazzino
Min: 1
Mult.: 1

Data Line Panel Mount Screw 24 VDC - 40 C + 85 C 61 mm 30.5 mm
Citel Protezioni da sovratensione industriali 4-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 24V, screw terminals 13A magazzino
Min: 1
Mult.: 1

Signal Line Chassis Mount Screw 28 VDC - 50 C + 85 C 120 mm 60 mm 35 mm
Citel Protezioni da sovratensione industriali 4-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 12V, screw terminals 4A magazzino
Min: 1
Mult.: 1

Signal Line Chassis Mount Screw 12 VDC - 50 C + 85 C 120 mm 60 mm 35 mm
Citel Protezioni da sovratensione industriali DD9-24V D-sub Data Line Surge Protectice Device (SPD) , 24V, 15 wire+G 1A magazzino
Min: 1
Mult.: 1

Data Line Panel Mount Screw 24 VDC 300 mA - 50 C + 85 C 61 mm 40.6 mm
Citel Protezioni da sovratensione industriali 1-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 24V, screw terminals 44A magazzino
Min: 1
Mult.: 1

Signal Line Chassis Mount Screw 28 VDC - 50 C + 85 C 68 mm 60 mm 25 mm
Citel Protezioni da sovratensione industriali UL497B, Dataline Surge Protective Device (SPD), 12V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated-Class I, Div. 2, Groups A, B, C & D 6A magazzino
Min: 1
Mult.: 1

DIN Rail 12 VDC 300 mA - 40 C + 85 C 90 mm 13 mm 65 mm
Citel Protezioni da sovratensione industriali UL497B/UL121201, Dataline Surge Protective Device (SPD), 24V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated-Class I, Div.2, Groups A, B, C & D 3A magazzino
Min: 1
Mult.: 1

DIN Rail 24 VDC 300 mA - 35 C + 85 C 90 mm 13 mm 65 mm
Citel Protezioni da sovratensione industriali 1-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 12V, screw terminals Non disponibile a magazzino
Min: 1
Mult.: 1

Signal Line Chassis Mount Screw 12 VDC 300 mA - 50 C + 85 C 68 mm 60 mm 25 mm
Citel Protezioni da sovratensione industriali UL497B, Dataline Surge Protectice Device (SPD), 6V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated- Class 1, Div. 2, Groups A, B, C & D Non disponibile a magazzino
Min: 8
Mult.: 8

DIN Rail Screw 6 VDC 300 mA - 40 C + 85 C 90 mm 13 mm 65 mm
Citel Protezioni da sovratensione industriali UL497B/UL121201 , Dataline Surge Protective Device (SPD), 48V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated- Class I, Div. 2, Groups A, B, C & D Non disponibile a magazzino
Min: 8
Mult.: 8

DIN Rail Screw 48 VDC 300 mA - 35 C + 85 C 90 mm 13 mm 65 mm